02 / Explore · Tools05 / Menu · Tools

Room Acoustics

Measure your room's reverberation time, calculate standing waves from its dimensions and the effect of materials, build a virtual room and listen. Approximate values; not a measuring instrument.

Room Acoustics

ROOM PLAN · 5.2 × 4.1 × 2.7 mMODE (1, 0, 0) · 33.0 Hz · AXIAL
AXIAL ━ · TANGENTIAL ─ · OBLIQUE ┄SCHROEDER ≈ 469 Hz

DIMENSIONS

VOLUME 57.6 m³

SURFACES

TYPICAL ABSORPTION
Floor
Ceiling
Walls

RT60 · SABINE

EYRING 500 Hz · 3.12 s
125 Hz
5.20 s
250 Hz
4.81 s
500 Hz
3.17 s
1 kHz
2.71 s
2 kHz
2.24 s
4 kHz
1.83 s

Save a room to compare against A, then change a material.

DECAY CURVE · INTERRUPTED NOISENO MEASUREMENT · CALC 3.17 s
CALC · STRONG REFLECTION · FRONT WALL · 2.3 ms · 0.81 m · FLUTTER ECHO LIKELY
MICROPHONE OFF

Measure with the speaker (not headphones). The test noise fades in, lasts two seconds and is cut off suddenly; the microphone listens to the decay. Nothing is recorded: only band levels. The values are approximate; this is not a measuring instrument.

How much reverb is in my room?

Room Acoustics shows how a room behaves with sound: the reverberation time (RT60, the time it takes sound to decay by 60 dB) is calculated in octave bands with the Sabine and Eyring formulas, standing waves (room modes) and the Schroeder frequency are found from the room's dimensions, and you can see how the result changes when you change the surface materials. The Measure button plays a short test noise through the speaker and cuts it, the microphone listens to the decay and gives an approximate RT60; nothing is recorded.

How is room acoustics calculated?

  1. Enter the room's length, width and height with the sliders; the volume and the modes change at once.
  2. Choose materials for the floor, ceiling and walls: the RT60 tiles are the calculated reverberation time of each octave band.
  3. Tap a line on the mode strip (or select with the arrow keys): the plan shows that mode's standing wave, and the dashed lines are its nodes.
  4. Save your room with Save as A, then change a material: you see the difference at 500 Hz as a percentage. Listen in the virtual room plays three hand claps with the same reverberation.
  5. To measure, turn on the speaker (not headphones), quieten the room and press Measure: the noise fades in, lasts two seconds and is cut off; the decay curve and the measured RT60 appear.

What is it used for?

  • Calculate your room's reverb

    Enter the dimensions and surface materials; RT60 is calculated in each octave band with the Sabine and Eyring formulas.

  • Try a change in advance

    Save your room with Save as A, then change a material such as a rug or curtains; you see the difference at 500 Hz as a percentage.

  • Find the bass modes

    Tap a line on the mode strip; the plan draws that mode's standing wave, with dashed lines for the nodes. It gives a hint when choosing where to listen.

  • Measure roughly with the microphone

    The Measure button plays a short test noise through the speaker and cuts it off; the microphone listens to the decay and gives an approximate RT60, and nothing is recorded.

How to read the results

  • The RT60 · SABINE tiles are the calculated time for sound to decay by 60 dB in each octave band; the highlighted tile is 500 Hz. In a dead room with lots of absorption, look at the EYRING 500 Hz value beside them.
  • In the mode strip the long, thick lines are axial modes, the strongest ones; below the SCHROEDER value modes are heard as separate. On the plan the dashed lines are the selected mode's nodes: if the listener ring sits near one, that frequency may sound weak there.
  • After a measurement the decay heading shows the measured RT60 next to CALC. TOO LOW means background noise covered the decay: T30 needs a 35 dB range, T20 25 dB. NOT MEASURABLE means the decay was shorter than 0.15 s or irregular.
  • CALC · STRONG REFLECTION names the first reflection arriving at most 40 ms after the direct sound and less than 6 dB quieter: surface, delay and extra path. FLUTTER ECHO LIKELY appears when the wall material absorbs less than 0.06 at 500 Hz.
  • All of it is approximate: the calculation assumes an empty, rectangular room with even surfaces, and a phone's microphone and speaker don't hear every frequency equally. The result is for comparison, not a measuring instrument's reading.

Formulas

V volume (m³), S total surface (m²), A equivalent absorption area (m², sum of surface × absorption coefficient), ᾱ mean absorption, c speed of sound (≈ 343 m/s).
MeasureFormulaWhen
Sabine RT600.161 · V / ALive rooms with little absorption
Eyring RT600.161 · V / (−S · ln(1 − ᾱ))Dry rooms with a lot of absorption
Room modec/2 · √((nx/L)² + (ny/W)² + (nz/H)²)Frequencies of the standing waves
Schroeder frequency2000 · √(RT60 / V)Below it, modes are heard individually

Why do room modes matter?

Between two opposite walls, standing waves form at frequencies whose half wavelength fits a whole number of times into the distance. At these frequencies the bass is strong in some places of the room and weak at the nodes. Axial modes (along one axis) are the strongest; tangential and oblique modes are weaker.

Below the Schroeder frequency the modes are sparse and separate; the room behaves like an instrument that rings note by note. Above it the modes crowd together and the reverberation time becomes statistically meaningful.

How is the measurement made?

The tool uses the interrupted noise method: pink noise fills the room, is cut off suddenly, and the microphone listens to how the sound decays in each octave band. RT60 is calculated from the line of the decay from −5 dB to −35 dB (T30) or −25 dB (T20).

Background noise masks the end of the decay. If the difference between the steady level and the background noise (the dynamic range) is below 35 dB for T30 or 25 dB for T20, no result is given for that band. Turning the volume up a little or quietening the room increases the range.

Frequently asked questions

Is this a measuring instrument?
No. A phone's or computer's speaker and microphone do not know the sound level and do not hear every frequency equally; the results are approximate and meant for comparison. The calculation also assumes the room is empty, rectangular and evenly finished.
Is sound recorded?
No. The microphone is open only during the measurement; the analyser reads the level of six octave bands frame by frame, and no sound sample is stored or sent. The microphone closes when the measurement ends, when you stop it or when you leave the page.
Where do the absorption coefficients come from?
From Sengpiel Audio's table of absorption coefficients of common materials (125-4000 Hz octave bands). The coefficient of the same material varies with the product and its mounting; the tool shows typical values.

· v1.15 · changelog

No cookies, no tracking. Details: Privacy notice (KVKK) On-device storage